US FDA Medical Device Registration

Medical Device Classification USA

FDA classifies Medical Devices into 3 risk-based categories, Class I, Class II and Class III wherein Class I devices are considered as low risk devices, and Class III are associated with high risk. The registration requirements and pathway vary with class of device.

Device ClassRisk

Registration Pathway

for approval

ILow Risk510(k) exempt
II

Moderate Risk

(With predicate device)

Premarket Notification/510(k)

Moderate Risk

(Without Predicate Device)

De-Novo application
IIIHigh RiskPremarket Approval (PMA)

U.S. FDA  Agent

Companies with no local offices in the U.S. must appoint a  U.S. FDA Agent to represent the manufacturer. The U.S. FDA agent must either reside in the U.S. or maintain a place of business in the U.S. The responsibilities to be fulfilled by the agent are pre-determined by the US FDA as a part of CFR regulations.

Navigate through the Frequently Asked Questions (FAQs) about US Agent.

Interactive Meetings with the US FDA

US FDA supports the manufacturers through various types of Q-Submission meetings to fulfil different objectives. Such meetings with the agency before initiation or during device development, prior to submission of US FDA medical device registration applications help manufacturers to optimize timelines and cost incurred for device commercialization.

 Medical Device Registration USA

The devices can be approved by the CDRH, FDA through any of the various registration pathways. They are listed as:

Class I Medical Devices: The class I devices are usually GMP and 510(k) submission exempt and do not require prior approval from the US FDA to market them in the U.S. Other requirements such as Establishment registration, Device listing, UDI, PMS etc. must be complied by the manufacturer.

Class II Medical devices: Medium risk devices with 510(k) approved predicate devices can opt for 510(k) Pre-market Notification (PMN), also called 510(k) registration. The subject device shall establish Substantial Equivalence (SE) with the identified and claimed predicate devices. This pathway is most widely adapted pathway for registration of devices in the U.S. Manufacturers of medium risk devices with no predicates may request for classification by the US FDA through De-Novo applications.

Class III Medical Devices: High risk class III device manufacturers must submit a Pre-Market Approval (PMA) application to the US FDA. The devices must undergo detailed clinical evaluation and manufacturer must submit detailed safety and efficacy data from clinical studies. The  US FDA would carry out QMS inspection as a part of assessment before issuing a Pre-Market Approval for the device.

Non-CDRH Medical Device Registrations

Based on indications of use, some border line products considered as medical devices in other countries such as, surgical respirators, disinfectants, combination products involve other Agencies such as, Centre for Disease Control (CDC), National Institute for Occupational Safety and Hazards (NIOSH), Environmental Protection Agency (EPA), Centre for Biological Evaluation and Research (CBER), Centre for Drug Evaluation and Research (CDER).

Post Approval Compliance Requirements for Medical Devices

 

All device manufacturers must comply with below listed post approval requirements:

  • Registration and Listing Requirement: Establishments of all device classes must be registered with FURLs database and the device must be listed after the approval is obtained and prior to marketing of device in the U.S. Some devices such as, radiation devices must comply with other requirements such as, accession number before they can be imported into U.S.
  • Unique Device Identification: All classes of devices must comply with the Unique Device Identification (UDI) regulations to market the devices in U.S.
  • Establishment FeesThe manufacturer must pay the annual establishment fees to maintain their establishment registration active and to continue marketing devices in the U.S. The US FDA has reduced fee structure for smaller entities with active Small Business Certificate.
  • Quality AuditsFor devices which are not GMP exempt the  US FDA may inspect the manufacturing establishment at any time for compliance with Quality Systems Regulations (QSR) in accordance with the 21 CFR 820.

Process flow

Post Approval Device Life Cycle Management

Freyr supports foreign manufacturers in end-to-end Medical Device lifecycle management, including post approval activities, such as:

  • Post approval change management - modifications to existing medical device approvals such as, addition of new variants, accessories; addition of new indications of use among others
  • Maintenance of approvals and registration through timely payment of MDUFA fees to the FDA
  • Liaising between the US FDA and Manufacturer

Freyr has exclusive delivery center in the U.S. with professional team to provide Regulatory support for manufacturers in maintaining quality and safety needed for approval. Freyr’s intelligence experts keenly observe Regulatory updates and keep the clients informed about steps to be taken for product compliance with current standard.

Summary

RiskDevice ClassQMS AuditPredicate AvailabilityRegulatory Pathway U.S. Agent US FDA Timelines
Low RiskINoNAExemptedYes1 Month
Medium RiskII

Yes

(post approval)

YesPMN/510(k)Yes9 - 12 Months
Medium RiskII

Yes

(post approval)

NoDe-Novo Classification RequestYes18 - 30 Months
High RiskIII

Yes

(pre approval)

NAPMAYes18 - 30 Months
 

Freyr’s Medical Device Device Registration Services

Freyr Expertise

Our Location in USA

150 College Road West, Ste 102,
Princeton NJ - 08540, USA